Respiratory Interventions

Showing 1–12 of 17 results

Covidien Nellcor™ Adult/Pediatric Colorimetric CO2 Detector

To help verify endotracheal tube placement

With the Nellcor™ adult/pediatric colorimetric CO2 detector clinicians can confirm proper endotracheal tube (ETT) placement by assessing exhaled CO2.
The detector attaches directly to the endotracheal tube and responds quickly to exhaled CO2 by changing from purple to yellow.

Covidien Shiley™ Nasopharyngeal Airway

Extra Soft for Patient Comfort

The Shiley™ nasopharyngeal airway provides an open airway during suctioning and bronchoscopy. It is made of a soft material that helps minimize patient coughing and gagging, and protects the nasopharyngeal mucosa for repeated catheter passage.

Shiley™ Endobronchial Tube with Left/Right Polyurethane Cuff

The endobronchial tube allows for the inflation of one lung as indicated for thoracic surgery or intensive care. There is a right and a left Shiley™ endobronchial tube option depending on the lung that needs to be ventilated. The tube features a low pressure tracheal and bronchial cuff to minimize risk of mucosal damage. The specially designed bronchial cuff assists with location of the distal tip when verification is confirmed by a fiber-optic bronchoscope. There is a slight curve at the distal tip to assist with placement. There is also an x-ray opaque carinal hook for confirming placement.

Shiley™ Esophageal Endotracheal Double Lumen Airway

Establishes a Patent Airway When Placed in the Trachea or Esophagus.
For difficult or emergency airway management, enabling blind placement without a laryngoscope.

Shiley™ Evac Oral Endotracheal Tubes with TaperGuard™ Cuff

Reduces ventilator-associated pneumonia (VAP) by an average of 50%.
The need to reduce ventilator associated events is the primary reason the Shiley™ evac oral endotracheal tube with TaperGuard™ cuff is critical for all patients on a ventilator in the ICU.
Advanced airway protection
Subglottic secretion drainage (SSD) helps remove oral and/or gastric secretions from above the endotracheal tube cuff before they can be aspirated. Such aspirations may lead to a very serious complication known as VAP or Ventilator Associated Pneumonia.
SSD must be done with a specialized endotracheal tube with a separate dorsal suction lumen located just above the cuff. Based upon clinical evidence, the following organizations recommend the use of SSD to reduce the incidence of VAP:

  • SHEA Guidelines
  • American Thoracic Society/ Infectious Diseases Society of America (ATS/IDSA) – Level I
  • Centers for Disease Control (CDC) – Category II
  • American Association of Critical Care Nurses (AACN)
  • Agency for Healthcare Research and Quality (AHRQ)
  • The Shiley™ Evac endotracheal tube with TaperGuard™ cuff incorporates Shiley™ Evac technology.

    Shiley™ Evac Oral Tracheal Tube, SealGuard™, Murphy Eye

    SealGuard™ Basic and SealGuard™ Evac endotracheal tubes offer the same patented TaperGuard™ cuff technology, with an integrated cuff inflation line and integrated suction lumen. The SealGuard™ Evac endotracheal tube features an ulta-thin polyurethane cuff that permits lower cuff pressures to maintain proper tracheal seal. It also features a smooth Murphy eye for easy insertion and is suitable for both nasal and oral insertion.

    Shiley™ Laser Oral Murphy Eye Endotracheal Tubes

    The Laser-Flex™ tracheal tube is a stainless steel, dual cuffed or uncuffed tube used for ventilation during CO2 and KTP laser surgeries of the laryngeal or tracheal area. It is laser resistant, non-flammable, flexible stainless steel. This technology provides an airtight steel spiral design that prevents air leaks occurring along the tube length.

    Shiley™ Microlaryngeal Oral/Nasal Murphy Eye Endotracheal Tube

    Standard I.D. and O.D. on this longer length tube provide greater access to the surgical field during microlaryngeal surgery.

    Shiley™ Oral and Nasal RAE Endotracheal Tubes with TaperGuard™ Cuff

    Shiley™ oral and nasal RAE endotracheal tubes with TaperGuard™ cuff feature a preformed curve design intended to reduce kinks and disconnects, maintain a patent airway, and remove the circuits and connectors from the surgical field.
    In addition, the RAE tube features the TaperGuard™ cuff technology: A low-pressure cuff that exerts 29% less pressure on the trachea.

    Shiley™ Oral/ Nasal Endotracheal Tube With Taperguard™ Cuff And Murphy Eye With Preloaded Stylet

    With a prepared Shiley™ oral/ nasal endotracheal tube with TaperGuard™ cuff and stylet, clinicians have the tools they need in one sterile, easy-to-access pack — no preloading necessary.
    In addition, the Shiley™ oral/nasal endotracheal tube with TaperGuard™ cuff features a low-pressure cuff that exerts 29% less pressure on the trachea.

    Shiley™ Oral/Nasal Endotracheal Tube with Intermediate Cuff

    Shiley™ endotracheal tubes with intermediate cuff can be used for paediatric through adult patients.

  • Size options 3.0–4.5 mm feature an intermediate low-profile cuff to meet the unique needs of pediatric patients.
  • Size options 5.0–10.0 feature an intermediate high-volume, low-pressure cuff.
  • DEHP is very toxic and hazardous to organism health and its exposure has been shown to have many adverse effects.¹ Compared to the legacy version, the Shiley™ oral/nasal endotracheal tube with intermediate cuff is made with non-DEHP PVC material, which softens at body temperature and molds to the airway.

    Shiley™ Oral/Nasal Non-DEHP Murphy Eye Endotracheal Tubes

    Protecting the Smallest Patients

    For clinicians who are concerned about phthalates in products used with neonatal and pediatric patients, we now offer a range of cuffless endotracheal tubes made with a non-DEHP plasticizer.