HFNC Devices

Showing all 6 results

AIRVO 2

With its integrated flow generator and innovative oxygen delivery system, the AIRVO 2 provides an effective, versatile solution for the delivery of oxygen therapy.

  • Designed to exceed the ISO standard for respiratory humidification
  • Precise, convenient O2 delivery from 21 to 80%
  • Variety of Optiflow patient interfaces for upper and bypassed airways
  • Wide flow range: 5-50 L/min (increments of 5 L/min)
  • Simple controls
  • Integrated O2 mixing
  • Inbuilt O2 sensor
  • No probes or external air supply required
  • AIRVO 3

    The Airvo 3 is a respiratory support device that delivers warmed and humidified respiratory gases to spontaneously breathing patients through a variety of patient interfaces.

  • Optiflow™ high flow therapy device: Delivering a mobile, uninterrupted broader range of Optiflow High Flow Therapy.
  • Integrated battery: Enables 40* minutes of operating time to facilitate transport and patient mobilisation throughout the hospital environment, minimizing therapy interruption.
  • Control at your fingertips: Bright, colorful touch screen – designed to be our most intuitive and easy-to-use interface ever.
  • Data-driven decision making: Real-time respiratory parameters, and 24 hours of trend data, to monitor patient progress.
  • AirSpiral Heated Breathing Tube

    The AirSpiral heated breathing tube for Airvo 2 utilizes an advanced two-spiral design to help protect against condensate.

  • Tubing Clip: The molded clip attaches to clothes or bedding to allow positioning of the tube during use.
  • Integrated temperature sensor: No external probes, cables or adaptors required.
  • Ergonomically designed: Molded grips at both ends of the tube assist connection and disconnection.
  • Optiflow Adult + Nasal Interface

    Optiflow nasal high flow delivers respiratory support to your patients, by providing heated, humidified air and oxygen at flow rates up to 70 L/min through the unique Optiflow nasal cannula and delivered by a device such as the Airvo 2 nasal high flow system.

  • Evaqua™ technology is designed to reduce the formation of mobile condensate.
  • The three-way connector fits all F&P circuits, Airvo™ and F&P 850 systems.
  • An adjustable head strap provides a secure, soft fit.
  • The head strap clip removes the need for a lanyard.
  • Soft cheek pads are designed to add stability and reduce pressure on the face.
  • Contoured prongs for a softer fit.
  • Optiflow Junior 2 Nasal Interface

  • The Optiflow Junior 2 cannula uses Waveflex technology to allow for natural facial movement when a patient’s cheeks are compressed. This improves prong stability in the nostrils.
  • Optiflow Junior 2 offers a range of five cannula sizes with flow ranges from 0.5 to 25 L/min to provide respiratory support for even your smaller patients.
  • Wigglepads 2 retains the same technology as the original Wigglepads and applies it to unique shape of the Optiflow Junior 2 cannula.
  • The FlexiTube is made with a breathable material to reduce condensate build-up by allowing water vapor to diffuse through the membrane to the outside of the tubing.
  • Optiflow Tracheostomy Interface

    Optiflow nasal high flow delivers respiratory support to your patients, by providing heated, humidified air and oxygen at flow rates up to 70 L/min through the unique Optiflow nasal cannula and delivered by a device such as the Airvo 2 nasal high flow system.

  • Evaqua™ technology: Designed to reduce the formation of condensation.
  • 93% less condensate*: Connects to our AirSpiral™ breathing tube for 93% less condensate*
  • Stable Easy to use: Re-designed sputum guard provides stability and ease of use.