Pain & Airway Management

Showing 1–12 of 29 results

Basic Set

This procedure pack contains essential items needed for a number of common procedures including lumbar puncture, spinal anaesthesia, epidural anaesthesia, liver biopsy, etc.

 

Complete Refill Set for PCA

Presented in a peel-pack containing.

  • -1 PCA lockable capping device with lever and cord
  • -1 60 ml calibrated reservoir
  • -1 female/female Luer-lock adaptor (code 892)
  • -1 female Luer-lock obturator (code 888)
  • Epidural Catheter Mini Set (Peristyl Catheter + Needle + Filter + Syringe)

    Kit includes one 10 ml syringe for loss of resistance technique (code 1018.10) in addition to items in Mini-kit code 189.50.
    20/120

    Epidural Mini-Kit (Peripur Catheter + Needle + Filter)

    Mini-kit for epidural anaesthesia including:
    – 1 transparent polyurethane catheter with radiopaque lines, int. Ø 0.5 mm, ext. Ø 1.0 mm, length 90 cm, flexible tubing without stylet, closed distal tip with 3 lateral eyes (code 189.30), open distal tip without lateral eyes (code 189.60). Centimetre graduations from 5 to 20 cm from the distal tip. Proximal connector “Easy-lock” type.
    N.B. The black mark at the distal end allows the user to ensure that the entire catheter has been withdrawn. Resistant to kinking and stretching.
    – 1 catheter-guide which connects onto the needle hub and facilites insertion of the catheter into the needle and epidural space.
    – 1 Tuohy needle 17G – Length 90 mm with plastic transparent hub and removable wings (code 184.17). Graduated every centimetre.
    – 1 flat filter 0.22µm

    Epidural Mini-Kit (Peristyl Catheter + Needle + Filter)

    Mini-kit containing one catheter code 185.10, one 17G Tuohy needle with plastic hub (code 184.17)
    and one flat 0.22 µm filter (code 808.22).

    Epidural Set with Peribax Catheter (16G)

    Mini set for epidural anaesthesia containing :
    – 1 Tuohy needle 16 G, 80 mm long with transparent hub and removable wings.
    The needle has graduations every centimetre. The transparent hub allows to quickly visualize an accidental reflux of blood or of CSF.
    – 1 PEBAX catheter (polyether blockamide), 19 G, 90 cm long with open distal end (code 5191.601) or with closed distal end and 3 lateral eyes (code 5191.801).
    The catheter has markings every centimetre from 5 to 20 cm and a black mark at the distal end to ensure that the entire catheter has been withdrawn.
    A catheter guide which connects onto the Tuohy needle facilitates the insertion of the catheter in the epidural space.
    – 1 Easy-lock catheter hub with pre-mounted epidural filter 0.22 µm. Filter surface area : 4.3 cm², priming volume : 0.3 ml, pressure resistance : 5.2 bar
    – 1 10 ml syringe for loss of resistance technique
    – 1 yellow label for epidural access identification

    Epidural Set with Peribax catheter (18G)

    Mini set for epidural anaesthesia containing:
    1 Tuohy needle 18G, 80mm long with transparent hub and removable wings. Metallic stylet for codes 5191.087, 5191.387 and 5191.337, plastic stylet for codes 5191.3371 and 5191.3871.
    The needle has graduations every centimetre. The transparent hub allows to quickly visualize an accidental reflux of blood or of CSF.

    1 PEBAX catheter (polyether blockamide), 20G, 90cm long with open distal end (code 5191.087) or with closed distal end and 3 lateral eyes (codes 5191.337 / 5191.387 / 5191.3371 / 5191.3871). Codes 5191.337 and 5191.3371 have a catheter with flexible distal tip. The catheter has markings every centimetre from 5 to 20cm and a black mark at the distal end to ensure that the entire catheter has been withdrawn.
    A (yellow) catheter guide which connects onto the Tuohy needle facilitates the insertion of the catheter in the epidural space.

    1 Easy-lock catheter hub with pre-mounted epidural filter 0.22 µm. Filter surface area : 4.3cm², priming volume : 0.3ml, pressure resistance : 5.2 bar
    1 10ml syringe for loss of resistance technique
    1 yellow label for epidural access identification

    Epimatic

    Epimatic is a syringe allowing automatic location of the epidural space thanks to the continuous positive pressure applied on the plunger by an elastic strip.
    The anaesthetist insert the needle and use one hand to hold the ultra sounds probe in order to control the needle progression. He receives a visual confirmation of access of Tuohy needle to the epidural space.

    Syringe can be used either with liquid or air.
    20/240

    Filter

    0.22 µm (anti-bacterial) filter for regional anaesthesia (epidural, continuous plexus and peripheral nerve blocks…), for retaining microbial particles and contaminants contained in solutions. Luer-lock fittings.

    Filter

    0.22 µm (anti-bacterial) filters for retaining microbial particles and contaminants contained in solutions. Luer-lock fittings.
    Code 809.22 is radiosterilized.

    Freedom 5

    Freedom 5 has been specially designed for pain management in the Accident and Emergency department or in the recovery room for the treatment of postoperative pain. This product is also indicated for pain treatment of patients suffering from sickle cell disease.